FANUC NC controller, servo amplifier, servo power supply, control board, single control circuit board (motherboard, CPU board, backplane, plug-in board, power board, main board, I/O board, AXIS board, SPIF board, CRT board , PSU board, FSRM board, SRAM board, DRAM board, FSRM power board), ensfh.
A06BSearje | A06B-6066-H244 | A06B-6078-H211 | A06B-6078-H306 | A06B-6079-H105 | A06B-6087-H137 |
A06B-6079-H206 | A06B-6079-H208 | A06B-6079-H209 | A06B-6080-H301 | A06B-6087-H130 | |
A06B-6080-H305 | A06B-6080-H307 | A06B-6080-H309 | A06B-6081-H103 | A06B-6087-H115 | |
A06B-6087-H126 | A06B-6089-H203 | A06B-6093-H101 | A06B-6093-H102 | A06B-6140-H015 | |
A06B-6093-H111 | A06B-6093-H151 | A06B-6102-H211 | A06B-6102-H215 | A06B-6134-H203 | |
A06B-6102-H520 | A06B-6110-H026 | A06B-6110-H030 |
Diskriminaasje en reparaasje fan mienskiplike flaters yn FANUC.
SVM-fout: LED-display 2, hoe't jo it alaarm fuortsmite.SPM-mislearring: LED-display 19, hoe kin it alarm fuortsmite?
SVM alarm koade 2.
(1) ynhâld: de frekwinsje converter kontrolearret de lege spanning fan de macht oanbod.
(2) wichtichste oarsaken en eliminaasje metoaden.
(a) befêstiget de 3-faze ynfierspanning fan 'e fersterker (moat grutter wêze as of lyk oan 0,85 kear de nominearre ynfierspanning).
(b) befêstiget de 24V-spanningsútfier fan PSM (normaal: 22.8V of mear).
(c) befêstigje Connector, Kabel (CXA2A/B).
(d) ferfange SVM.
SPM alarm koades 19, 20.
De offset spanning fan U-faze (alarmkoade 19) en V-faze (alarmkoade 20) stromdeteksjekring is te grut. Detect as oandreaun.
As in alarm optreedt, ferfange asjebleaft de SPM.As de SPM-kontrôle printe circuit board is krekt ferfongen, befêstigje asjebleaft it ynstekken fan 'e ferbining tusken de macht ienheid en de SPM control printe circuit board.